Fifteen waveguide bands from WR430 through WR28.
HOME » Waveguide, RF & Microwave Components » Crossguide Directional Couplers
Crossguide Directional Couplers
Crossguide directional couplers sample travelling-wave power through a secondary guide crossing the main RF path. Dolph lists WR430–WR28 configurations with waveguide or coaxial sample ports, 18–60 dB coupling and 18 dB minimum directivity in the published tables. Choose the exact band and port layout, then check whether directivity, sample power and connector limits suit the measurement.
Dolph Microwave crossguide directional couplers provide controlled signal sampling or injection in WR430 through WR28 rectangular waveguide systems. Published configurations include four waveguide ports, three waveguide ports, and two waveguide ports with one coaxial sampling port.
Standard nominal coupling values are 20, 30, 40, 50 and 60 dB. The published model tables cover an 18–60 dB coupling range, 18 dB minimum directivity, 10–20% typical operating bandwidth, aluminum or copper construction and multiple IEC/EIA flange arrangements. Non-standard port layouts and coupling requirements are available subject to engineering review.
Compact directional sampling where installation space matters
A crossguide directional coupler transfers part of the main-line signal to a secondary waveguide or coaxial sample port. Coupling describes the sample level relative to the incident signal; directivity describes rejection of the opposite travelling wave. They are separate limits and neither establishes the main-line power rating.
The published minimum directivity is 18 dB. Check whether opposite-direction leakage is acceptable for the intended reflected-power measurement, particularly when the reflected signal is small. The broadwall directional coupler uses a different sampling structure; compare its selected-model data rather than assuming either type is always more accurate.
Performance values for initial selection
Standard nominal values are 20, 30, 40, 50 and 60 dB.
Separates the desired travelling-wave sample from the opposite direction.
Most listed models are 1.10; WR28 models are listed at 1.15.
Published for the specified operating bandwidth.
The published bandwidth statements use percentages with different descriptions. Provide exact start and stop frequencies and the required coupling tolerance across them; a percentage alone does not establish the full usable WR band.
The standard sheet does not publish CW power, peak power, duty cycle, pressure sealing, temperature range or environmental qualification. Provide these conditions for engineering review and written confirmation.
Overall length and port orientation vary with waveguide size, flange selection and coupled-port style. Use the approved drawing for mechanical integration.
Select the coupling interface that fits the assembly
Four Waveguide Ports
A four-port all-waveguide arrangement with two main-line ports and two secondary-line waveguide ports. The specification uses the DH-xxW+C… model family.
Three Waveguide Ports
An all-waveguide arrangement with two main-line ports and one secondary waveguide port. The specification uses the DH-xxWL+C… model family.
Two Waveguide Ports + One Coax Port
Two main-line waveguide ports with a compact coaxial sampling output. Published table options use Type-N in lower bands and SMA in higher bands; other connector codes remain subject to frequency and layout review.
Model coverage by port configuration
Each table retains frequency, bandwidth, VSWR, coupling, directivity, waveguide, flange, connector and material details. Scroll horizontally on smaller screens.
Style 1 — Four Waveguide Ports DH-xxW+C… | Main-line and secondary-line waveguide ports ⌄
| Model No. | Freq. Range (GHz) | Operating BW (%) | Main VSWR Max. | Secondary VSWR Max. | Coupling (dB) | Directivity Min. (dB) | IEC WG | EIA WG | Flange | Material |
|---|---|---|---|---|---|---|---|---|---|---|
| DH-22W+C… | 1.72–2.61 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R22 | WR430 | FDP / FDM | Al / Cu |
| DH-26W+C… | 2.17–3.30 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R26 | WR340 | FDP / FDM | Al / Cu |
| DH-32W+C… | 2.60–3.95 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R32 | WR284 | FDP / FDM | Al / Cu |
| DH-40W+C… | 3.22–4.90 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R40 | WR229 | FDP / FDM | Al / Cu |
| DH-48W+C… | 3.94–5.99 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R48 | WR187 | FDP / FDM | Al / Cu |
| DH-58W+C… | 4.64–7.05 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R58 | WR159 | FDP / FDM | Al / Cu |
| DH-70W+C… | 5.38–8.17 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R70 | WR137 | FDP / FDM | Al / Cu |
| DH-84W+C… | 6.57–9.99 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R84 | WR112 | FBP / FBM / FBE | Al / Cu |
| DH-100W+C… | 8.20–12.40 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R100 | WR90 | FBP / FBM / FBE | Al / Cu |
| DH-120W+C… | 9.84–15.0 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R120 | WR75 | FBP / FBM / FBE | Al / Cu |
| DH-140W+C… | 11.9–18.0 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R140 | WR62 | FBP / FBM / FBE | Al / Cu |
| DH-180W+C… | 14.5–22.0 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R180 | WR51 | FBP / FBM / FBE | Al / Cu |
| DH-220W+C… | 17.6–26.7 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R220 | WR42 | FBP / FBM / FBE | Al / Cu |
| DH-260W+C… | 21.7–33.0 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R260 | WR34 | FBP / FBM / FBE | Al / Cu |
| DH-320W+C… | 26.3–40.0 | 10–20 | 1.15 | 1.15 | 18–60 | 18 | R320 | WR28 | FBP / FBM / FBE | Al / Cu |
Style 2 — Three Waveguide Ports DH-xxWL+C… | Two main-line ports and one waveguide coupling port ⌄
| Model No. | Freq. Range (GHz) | Operating BW (%) | Main VSWR Max. | Secondary VSWR Max. | Coupling (dB) | Directivity Min. (dB) | IEC WG | EIA WG | Flange | Material |
|---|---|---|---|---|---|---|---|---|---|---|
| DH-22WL+C… | 1.72–2.61 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R22 | WR430 | FDP / FDM | Al / Cu |
| DH-26WL+C… | 2.17–3.30 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R26 | WR340 | FDP / FDM | Al / Cu |
| DH-32WL+C… | 2.60–3.95 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R32 | WR284 | FDP / FDM | Al / Cu |
| DH-40WL+C… | 3.22–4.90 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R40 | WR229 | FDP / FDM | Al / Cu |
| DH-48WL+C… | 3.94–5.99 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R48 | WR187 | FDP / FDM | Al / Cu |
| DH-58WL+C… | 4.64–7.05 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R58 | WR159 | FDP / FDM | Al / Cu |
| DH-70WL+C… | 5.38–8.17 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R70 | WR137 | FDP / FDM | Al / Cu |
| DH-84WL+C… | 6.57–9.99 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R84 | WR112 | FBP / FBM / FBE | Al / Cu |
| DH-100WL+C… | 8.20–12.40 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R100 | WR90 | FBP / FBM / FBE | Al / Cu |
| DH-120WL+C… | 9.84–15.0 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R120 | WR75 | FBP / FBM / FBE | Al / Cu |
| DH-140WL+C… | 11.9–18.0 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R140 | WR62 | FBP / FBM / FBE | Al / Cu |
| DH-180WL+C… | 14.5–22.0 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R180 | WR51 | FBP / FBM / FBE | Al / Cu |
| DH-220WL+C… | 17.6–26.7 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R220 | WR42 | FBP / FBM / FBE | Al / Cu |
| DH-260WL+C… | 21.7–33.0 | 10–20 | 1.10 | 1.15 | 18–60 | 18 | R260 | WR34 | FBP / FBM / FBE | Al / Cu |
| DH-320WL+C… | 26.3–40.0 | 10–20 | 1.15 | 1.15 | 18–60 | 18 | R320 | WR28 | FBP / FBM / FBE | Al / Cu |
Style 3 — Two Waveguide Ports + One Coax Port DH-xxWL+C… | Compact coaxial sampled output ⌄
| Model No. | Freq. Range (GHz) | Operating BW (%) | Main VSWR Max. | Secondary VSWR Max. | Coupling (dB) | Directivity Min. (dB) | IEC WG | EIA WG | Flange | Coupled Connector | Material |
|---|---|---|---|---|---|---|---|---|---|---|---|
| DH-22WL+C… | 1.72–2.61 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R22 | WR430 | FDP / FDM | Type-N | Al / Cu |
| DH-26WL+C… | 2.17–3.30 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R26 | WR340 | FDP / FDM | Type-N | Al / Cu |
| DH-32WL+C… | 2.60–3.95 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R32 | WR284 | FDP / FDM | Type-N | Al / Cu |
| DH-40WL+C… | 3.22–4.90 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R40 | WR229 | FDP / FDM | Type-N | Al / Cu |
| DH-48WL+C… | 3.94–5.99 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R48 | WR187 | FDP / FDM | Type-N | Al / Cu |
| DH-58WL+C… | 4.64–7.05 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R58 | WR159 | FDP / FDM | Type-N | Al / Cu |
| DH-70WL+C… | 5.38–8.17 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R70 | WR137 | FDP / FDM | Type-N | Al / Cu |
| DH-84WL+C… | 6.57–9.99 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R84 | WR112 | FBP / FBM / FBE | SMA | Al / Cu |
| DH-100WL+C… | 8.20–12.40 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R100 | WR90 | FBP / FBM / FBE | SMA | Al / Cu |
| DH-120WL+C… | 9.84–15.0 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R120 | WR75 | FBP / FBM / FBE | SMA | Al / Cu |
| DH-140WL+C… | 11.9–18.0 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R140 | WR62 | FBP / FBM / FBE | SMA | Al / Cu |
| DH-180WL+C… | 14.5–22.0 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R180 | WR51 | FBP / FBM / FBE | SMA | Al / Cu |
| DH-220WL+C… | 17.6–26.7 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R220 | WR42 | FBP / FBM / FBE | SMA | Al / Cu |
| DH-260WL+C… | 21.7–33.0 | 10–20 | 1.10 | 1.25–1.50 | 18–60 | 18 | R260 | WR34 | FBP / FBM / FBE | SMA | Al / Cu |
| DH-320WL+C… | 26.3–40.0 | 10–20 | 1.15 | 1.25–1.50 | 18–60 | 18 | R320 | WR28 | FBP / FBM / FBE | SMA | Al / Cu |
Build the required part number
The complete code identifies waveguide size, directional configuration, coupling value, connector, connector interface, flange arrangement and material.
Confirm the build against the approved configuration
Published options are aluminum and copper. The exact material should be confirmed in the part number, quotation and drawing.
The specification lists corrosion protection with a black top coat. Other finishes or paint colors may be reviewed upon request.
Overall dimensions and port orientation vary by waveguide, flange and coupled-port configuration. Use the approved drawing for integration.
State main-line CW and peak power, duty cycle, mismatch and environment. Estimate sample power from the selected coupling and confirm the connector and sensor limits. Terminate unused secondary ports as required by the port arrangement; an open unused port can change the measurement.
Continue product comparison and technical selection
Crossguide coupler selection questions
What frequency and waveguide sizes are covered?⌄
Which coupling values are standard?⌄
Can the coupled output be waveguide or coaxial?⌄
Are all connector families available at every frequency?⌄
Is power handling included in the standard table?⌄
Can a non-standard port layout be reviewed?⌄
What finish is supplied?⌄
What should be approved before production?⌄
Send the frequency band, coupling and port drawing
Dolph Microwave can review a standard model or project-specific crossguide layout and confirm the electrical, mechanical and finish details in the quotation and drawing.